LANZILLOTTI, MARCO

LANZILLOTTI, MARCO  

AE Metrologia applicata e ingegneria  

Mostra records
Risultati 1 - 20 di 24 (tempo di esecuzione: 0.011 secondi).
Citazione Data di pubblicazione Autori File
10 V, 1 Ω, 10 kΩ high accuracy standard setup for calibration of multifunction electrical instruments and for inter-laboratory comparisons / Capra, PIER PAOLO; Cerri, Roberto; Galliana, Flavio; Lanzillotti, Marco. - ONLINE:SI and new electrical standards / SI et nouvelles références en électricité(2017). (Intervento presentato al convegno 18th International Congress of Metrology, 07006 (2017) tenutosi a paris nel 19/21 SETTEMBRE 2017) [10.1051/metrology/201707006]. 2017 CAPRA, PIER PAOLOCERRI, ROBERTOGALLIANA, FLAVIOLANZILLOTTI, MARCO metrology_metr2017_07006.pdf
AC-DC current transfer difference estimation of thin-film multijunction TCs up to 1 MHz / Trinchera, BRUNO OTTAVIO; Tet, Luca Roncaglione; Lanzillotti, Marco. - (2016), pp. 1-2. [10.1109/CPEM.2016.7540676] 2016 TRINCHERA, BRUNO OTTAVIOLANZILLOTTI, MARCO + 07540676_IAC.pdf
Accurate comparison between INRIM and a secondary calibration laboratory using a top-class multifunction electrical calibrator / Galliana, Flavio; Lanzillotti, Marco. - In: MEASUREMENT. - ISSN 0263-2241. - 103:(2017), pp. 353-360. [http://dx.doi.org/10.1016/j.measurement.2017.02.052] 2017 GALLIANA, FLAVIOLANZILLOTTI, MARCO MEAS_103.pdfart_cal_rev2_final.pdf
Analisi del divisore automatico di Tensione continua di precisione a rapporti fissi sviluppato all’INRIM / Galliana, Flavio; Capra, PIER PAOLO; Cerri, Roberto; Lanzillotti, Marco. - (2019), pp. 1-18. [10.13140/RG.2.2.28844.31367] 2019 FLAVIO GALLIANAPIER PAOLO CAPRAROBERTO CERRIMARCO LANZILLOTTI -
ANALISI DI IMPATTO DELLA REVISIONE DEL SISTEMA INTERNAZIONALE SULLA REALIZZAZIONE DELLE GRANDEZZE ELETTROMAGNETICHE IN INRIM / Agosto, A.; Basso, V.; Callegaro, L.; Capra, P. P.; Cassiago, C.; Crotti, G.; Cerri, R.; D’Elia, V.; Fissore, F.; Galliana, F.; Gasparotto, E.; Giusio, V.; Lanzillotti, M.; Rocchino, L.; Roncaglione Tet, L.; Serazio, D.; Trinchera, B.; Toso, L.; Varetto, G.; Vizio, G.. - (2019), pp. i-3. 2019 A. AgostoV. BassoL. CallegaroP. P. CapraC. CassiagoG. CrottiR. CerriF. FissoreF. GallianaE. GasparottoV. GiusioM. LanzillottiL. RocchinoL. Roncaglione TetD. SerazioB. TrincheraL. TosoG. VarettoG. Vizio + -
Automated precision DC voltage fixed ratios divider / Galliana, Flavio; Capra, Pier Paolo; Cerri, Roberto; Lanzillotti, Marco. - In: MEASUREMENT. - ISSN 0263-2241. - 122:(2018), pp. 291-296. [10.1016/j.measurement.2018.03.045] 2018 Galliana, FlavioCapra, Pier PaoloCerri, RobertoLanzillotti, Marco MEAS_122.pdfart_DIVISORE_rev2 (1).pdf
Automated setup to accurately calibrate electrical dc voltage generators / Galliana, Flavio; Capra, Pier Paolo; Cerri, Roberto; Lanzillotti, Marco. - In: MEASUREMENT. - ISSN 0263-2241. - 123:(2018), pp. 129-134. [10.1016/j.measurement.2018.03.062] 2018 Galliana, FlavioCapra, Pier PaoloCerri, RobertoLanzillotti, Marco MEAS_123.pdfART_TAR_CAL_rev1ter (1).pdf
Determinazione del coefficiente di temperatura di resistori campione nel range 1 ohm – 100 Mohm / RONCAGLIONE TET, Luca; Lanzillotti, Marco; Francese, Claudio; Capra, PIER PAOLO; Galliana, Flavio. - (2021), pp. 1-19. 2021 Luca RoncaglioneMarco LanzillottiClaudio FrancesePier Paolo CAPRAFlavio Galliana RT-2021-34.pdf
DMMs as voltage ratio standards: a 20 years’ report / Capra, P. P.; Galliana, F.; Lanzillotti, M.; Sosso, A.; Durandetto, P.; RONCAGLIONE TET, L.; Francese, C.. - (2022), pp. 68-72. (Intervento presentato al convegno 25th IMEKO TC-4 international symposium on measurement of Electrical quantities 23rd international workshop on ADC and DAC modelling and testing tenutosi a brescia nel settembre 2022). 2022 P. P. CAPRAF. GALLIANAM. LANZILLOTTIA. SossoP. DURANDETTOL. RONCAGLIONE TETC. Francese IMEKO_2022_DMM.pdf
EM-K13.a and b DC electrical Resistance Key Comparisons between INRIM and BIPM on 1 Ω and 10 kΩ Resistors / Capra, PIER PAOLO; Galliana, Flavio; Borla, Michela; Lanzillotti, Marco; RONCAGLIONE TET, Luca; Francese, Claudio. - (2023), pp. 1-17. [10.13140/rg.2.2.19922.53447] 2023 Pier Paolo CapraFlavio GallianaMichela BorlaMarco LanzillottiLuca Roncaglione TetClaudio Francese RT-2023-29.pdf
Evaluation of a high-precision digital multimeter by the laboratory of calibration of multifunction electrical instruments of INRIM / Galliana, Flavio; Lanzillotti, Marco. - In: METROLOGY AND MEASUREMENT SYSTEMS. - ISSN 2080-9050. - 26:2(2019), pp. 283-296. [10.24425/mms.2019.128356] 2019 Flavio GallianaMarco Lanzillotti 06_MMS-2019-2_06-12(1).pdfGALLIANA post print.pdf
EVALUATION OF THE HIGH PRECISION TRANSMILLE MOD. 8081 DIGITAL MULTIMETER BY THE INRIM CALIBRATION LABORATORY OF MULTIFUNCTION ELECTRICAL INSTRUMENTS / Galliana, F.; Lanzillotti, M.. - (2016), pp. 1-44. 2016 F. GallianaM. Lanzillotti rt_23_2016.pdf
Evaluation of the TRANSMILLE mod. 8081 high precision digital multimeter by the INRIM calibration laboratory of multifunction electrical instruments / Galliana, F.; Lanzillotti, M.. - (2016), pp. 1-44. 2016 F. GallianaM. Lanzillotti rt_23_2016.pdf
Measurement setup to characterize electrical standards / Capra, Pier Paolo; Cerri, Roberto; Galliana, Flavio; Lanzillotti, Marco; Pollarolo, Alessio; Roccato, Paolo. - (2019), p. 11003. (Intervento presentato al convegno 19th International Congress of Metrology tenutosi a PARIGI nel settembre 2019) [10.1051/metrology/201911003]. 2019 Capra, Pier PaoloCerri, RobertoGalliana, FlavioLanzillotti, MarcoRoccato, Paolo + metrology_cim2019_11003.pdf
NRIM-BIPM.EM-K13.a and b Key Comparisons of Electrical Resistance Standards using 1 Ω and 10 kΩ Resistors as Travelling Standards: INRIM results / Capra, PIER PAOLO; Galliana, Flavio; Francese, Claudio; Lanzillotti, Marco; RONCAGLIONE TET, Luca. - (2023), pp. 1-12. 2023 Pier Paolo CapraFlavio GallianaClaudio FranceseMarco LanzillottiLuca Roncaglione Tet RT-2023-03.pdf
Portable DC Voltage and Resistance Reference with Switching Unit for Calibration of Electrical Precision Multifunction Instruments / Capra, PIER PAOLO; Galliana, Flavio; Cerri, Roberto; Lanzillotti, Marco; Pollarolo, Alessio; Francone, Fulvio. - (2018). (Intervento presentato al convegno CONFERENCE ON PRECISE ELECTROMAGNETIC MEASUREMENTS tenutosi a PARIS nel JULY 2018). 2018 PIER PAOLO CAPRAFLAVIO GALLIANAROBERTO CERRIMARCO LANZILLOTTIFULVIO FRANCONE + CPEM-S401-10-1801261129.pdf
Report of a Multilateral Accurate Measurement Comparison on a High-Precision Multimeter to Evaluate the Traceability Transfer from INRIM in the Field of Low-Frequency Electrical Quantities / Galliana, Flavio; Lanzillotti, Marco. - In: MAPAN. JOURNAL OF METROLOGY SOCIETY OF INDIA. - ISSN 0970-3950. - 34:4(2019), pp. 473-478. [10.1007/s12647-019-00317-9] 2019 Galliana, FlavioLanzillotti, Marco 2352902.pdf
Stabilità di un multimetro di elevata accuratezza di recente produzione mediante confronto con il sistema di riferimento del laboratorio di taratura di strumenti elettrici multifunzione dell’INRIM / Galliana, Flavio; Lanzillotti, Marco. - (2015), pp. 1-43. 2015 GALLIANA, FLAVIOLANZILLOTTI, MARCO -
Taratura di calibratori multifunzione di alto Livello nelle funzioni resistenza in corrente continua e corrente continua / Lanzillotti, M.; Capra, P. P.; Galliana, F.. - (2019), pp. 1-43. 2019 M. LanzillottiP. P. CapraF. Galliana -
Taratura di calibratori multifunzione di alto Livello nella funzione tensione continua / Lanzillotti, Marco; Capra, PIER PAOLO; Galliana, Flavio. - (2019), pp. 1-49. [10.13140/rg.2.2.15422.54085] 2019 Marco LanzillottiPier Paolo CapraFlavio Galliana -