Sfoglia per Autore  

Opzioni
Mostrati risultati da 21 a 40 di 64
Citazione Data di pubblicazione Autori File
Final report on CCM.M-K4: Key comparison of 1 kg stainless steel mass standards / Becerra, Luis Omar; Orys, Michael; Chung, Jin Wan; Davidson, Stuart; Fuchs, Peter; Jacques, Claude; Jian, Wang; Kubarych, Zeina J; Kumar, Anil; Malengo, Andrea; Fen, Kitty; Medina, Nieves; Meury, Paul-André; Mizushima, Shigeki; Picard, Alain; Steyn, Ronél; Zelenka, Zoltan. - In: METROLOGIA. - ISSN 1681-7575. - 51:1A(2014), pp. 07009-07009. [10.1088/0026-1394/51/1A/07009] 2014 Malengo, Andrea + CCM.M-K4 1 kgmass.pdf
Mathematical modelling to support traceable dynamic calibration of pressure sensors / Matthews, C; Pennecchi, FRANCESCA ROMANA; Eichstädt, S; Malengo, Andrea; Esward, T; Smith, I; Elster, C; Knott, A; Arrhén, F; Lakka, A.. - In: METROLOGIA. - ISSN 0026-1394. - 51:3(2014), p. 326. [doi:10.1088/0026-1394/51/3/326] 2014 PENNECCHI, FRANCESCA ROMANAMALENGO, ANDREA + -
Calibration Curves Computing – CCC software / Malengo, Andrea; Pennecchi, FRANCESCA ROMANA; Spazzini, PIER GIORGIO. - (2015). 2015 MALENGO, ANDREAPENNECCHI, FRANCESCA ROMANASPAZZINI, PIER GIORGIO -
EURAMET Calibration Guide CG 18 V. 4.0 Guidelines of Calibration of Non - Automatic Weighing Instruments / Davidson, Stuart; Fritsch, Klaus; Grum, Matej; Malengo, Andrea; Medina, Nieves; Popa, George; Schnell, Norbert. - (2015). 2015 Andrea Malengo + I-CAL-GUI-018_Calibration_Guide_No._18_web.pdf
Results of the second round of International Comparison for volume of Liquids at 20 L and 100 mL / Malengo, Andrea. - (2015). (Intervento presentato al convegno Fluid Flow Measurement 9th International Symposium tenutosi a Arlington, Virginia nel 14-17 Aprile 2015). 2015 MALENGO, ANDREA ResultsBIPM-CIPMKey_ResultsSecondRoundInternational.pdfResultsBIPM-CIPMKey_ResultsSecondRoundInternational.pdf
BIPM/CIPM key comparison CCM.FF-K4.1.2011. Final report for volume of liquids at 20 L and 100 mL / Arias, R; Maldonado, M; Batista, E; Jintao, W; Malengo, A; Malta, D; Ondodro, D; Penttinen, O; Smits, E; Wright, J. - In: METROLOGIA. - ISSN 1681-7575. - 52:07011(2015), pp. 07011-07011. [10.1088/0026-1394/52/1A/07011] 2015 Malengo, A + CCM.FF-K4.1.2011.pdf
Final report of CCM key comparison of mass standards CCM.M-K6, 50 kg / J. Abbott, Patrick; O. Becerra, Luis; Borys, Michael; Davidson, Stuart; Jacques, Claude; Lee, Sungjun; Loayza, Víctor; Malengo, Andrea; Medina, Ma Nieves. - In: METROLOGIA. - ISSN 0026-1394. - 52:1A(2015), pp. 07004-07004. [10.1088/0026-1394/52/1A/07004] 2015 MALENGO, ANDREA + CCM.M-K6 50 kg.pdf
La taratura dei campioni di massa di riferimento dell'INRIM / Malengo, Andrea; Torchio, Davide. - Rapporto tecnici INRIM 41/2016:(2016). 2016 MALENGO, ANDREATORCHIO, DAVIDE -
Uncertainty evaluation for magnetic dipole models: ESA study “Uncertainty budgets for magnetic dipole models” / Pennecchi, FRANCESCA ROMANA; Malengo, Andrea; Bich, Walter; Basso, Vittorio; Toso, Luca. - (2016), pp. 237-242. (Intervento presentato al convegno Metrology for Aerospace (MetroAeroSpace), 2016) [10.1109/MetroAeroSpace.2016.7573218]. 2016 PENNECCHI, FRANCESCA ROMANAMALENGO, ANDREABICH, WALTERBASSO, VITTORIOTOSO, LUCA Modelling_of_PMU_uncertainty_by_means_of_Monte_Carlo_method.pdf
Assessment of uncertainty affecting equivalent magnetic dipole models / Nicoletto, M.; Boschetti, D.; Marziali, I.; Pennecchi, FRANCESCA ROMANA; Basso, Vittorio; Malengo, Andrea; Junge, A.. - (2016), pp. 7-12. [10.1109/AeroEMC.2016.7504540] 2016 PENNECCHI, FRANCESCA ROMANABASSO, VITTORIOMALENGO, ANDREA + ASSESSMENT OF UNCERTAINTY AFFECTING EQUIVALENT MAGNETIC DIPOLE MODELS-1.pdfMagnetic dipole 07504540.pdf
Air–vacuum transfer; establishing traceability to the new kilogram / Davidson, Stuart; Berry, James; Abbott, Patrick; Marti, Kilian; Green, Richard; Malengo, Andrea; Nielsen, Lars. - In: METROLOGIA. - ISSN 0026-1394. - 53:5(2016), pp. A95-A113. [10.1088/0026-1394/53/5/A95] 2016 MALENGO, ANDREA + Davidson_2016_Metrologia_53_A95.pdfMetrologia Spec Ed 2016_V2.11.pdf
Buoyancy contribution to uncertainty of mass, conventional mass and force / Malengo, Andrea; Bich, Walter. - In: METROLOGIA. - ISSN 0026-1394. - 53:2(2016). 2016 MALENGO, ANDREABICH, WALTER conventional value 2015 11 24 black.pdfMalengo_2016_Metrologia_53_762.pdf
Progress in the realization of the INRIM centrifugal balance for mass measurements in space / Malengo, Andrea; LA PIANA, Gaetano; Martini, Giovanni; Rivetti, Antonio. - (2016), pp. 593-597. (Intervento presentato al convegno Metrology for Aerospace (MetroAeroSpace) tenutosi a Firenze nel 22-23 giugno 2016) [10.1109/MetroAeroSpace.2016.7573283]. 2016 MALENGO, ANDREALA PIANA, GAETANO + 07573283.pdfArticolo_Metroaerospace_Malengo 4 (1).pdf
Density measurements of IAPSO seawater by single sinker hydrostatic balance / Giuliano Albo, P. A.; Lago, S.; Romeo, R.; Malengo, A.. - (2017). (Intervento presentato al convegno 21 st European Conference on Thermophysical Properties). 2017 P. A. Giuliano AlboS. LagoR. RomeoA. Malengo -
Sistema per la pesata idrostatica di campioni di massa da 2 kg a 50 kg per la determinazione del volume e densità / Malengo, A.; Torchio, D.; Santiano, M.. - (2017). 2017 A. MalengoD. TorchioM. Santiano -
The final report for CCM.M-K7: key comparison of 5 kg, 100 g, 10 g, 5 g and 500 mg stainless steel mass standards / Lee, Sungjun; Borys, Michael; Abbott, Patrick; Becerra, Luis Omar; Eltawil, Alaaeldin A; Jian, Wang; Malengo, Andrea; Medina, Nieves; Snegov, Victor; Wüthrich, Christian; Scholz, Frank. - In: METROLOGIA. - ISSN 0026-1394. - 54:1A(2017), pp. 07001-07001. [10.1088/0026-1394/54/1A/07001] 2017 MALENGO, ANDREA + CCM.M-K7.pdf
Comparison between TEOS-10 estimated density and experimental density measured in IAPSO standard seawater by a single sinker hydrostatic balance / Alberto Giuliano Albo, P.; Lago, Simona; Romeo, Raffaella; Malengo, Andrea. - (2018). 2018 P. Alberto Giuliano AlboSimona LagoRaffaella RomeoAndrea Malengo Albis_ICPWS2018.pdf
Guidelines on the Determination of Uncertainty in Gravimetric Volume Calibration | TC-F | Version 3.0, 09/2018 / Malengo, Andrea; Batista, Elsa; Metaxiotou, Zoe; Lobo Robledo, Alfonso; Akcadag, Umit; Micic, Ljiljana. - (2018). 2018 Andrea Malengo + -
EURAMET Key Comparison EURAMET.M.FF-K4.1.2016: Volume comparison at 20 L, INRIM Results / Malengo, Andrea; Torchio, Davide; Leka, Adelina. - (2018). 2018 Andrea MalengoDavide TorchioLEKA, ADELINA -
Towards the Electrostatic Realization of the Kilogram / Pisani, Marco; Malengo, Andrea. - (2018), pp. 1-2. (Intervento presentato al convegno 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018)) [10.1109/CPEM.2018.8501237]. 2018 Pisani, MarcoMalengo, Andrea Towards the electrostatic realization of the kilogram.pdf
Mostrati risultati da 21 a 40 di 64
Legenda icone

  •  file ad accesso aperto
  •  file disponibili sulla rete interna
  •  file disponibili agli utenti autorizzati
  •  file disponibili solo agli amministratori
  •  file sotto embargo
  •  nessun file disponibile