Sfoglia per Autore
Construction and investigation of six Pt/Pd thermocouples to be used as secondary standards
2005 Astrua, Milena; Battuello, Mauro; Dematteis, R; Mangano, A.
Facility for the calibration of Pt/Pd thermocouples in the temperature range from 960 °C to 1500 °C
2006 Astrua, Milena; Battuello, Mauro; Girard, Ferruccio
Angle amplification for nanoradian measurements
2006 Pisani, Marco; Astrua, Milena
Statistical techniques for assessing the agreement between two instruments
2007 Ichim, D; Pennecchi, FRANCESCA ROMANA; Pisani, Marco; Astrua, Milena
Calibrazione di picoamperometri in corrente continua nel range 100 pA ÷100nA mediante uso di reti Hamon
2007 Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena; Gasparotto, E.
Use of a 100 MΩ step HAMON resistor for calibration of pico-ammeters in dc current in the range 100 pA ÷ 100 nA
2007 Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena; Gasparotto, E.
A 100 MΩ STEP HAMON GUARDED NETWORK TO IMPROVE THE TRACEABILITY LEVEL OF HIGH RESISTANCE UP TO 1GΩ
2007 Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena
Sub-nanoradian angle measurements
2007 Pisani, Marco; Astrua, Milena
A temperature variable high accuracy 10 kΩ resistor
2008 Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena
Facility for the measurement of the refractive index of glass prism
2008 Astrua, Milena
“Realizzazione di un resistore campione da 10 kΩ di elevata accuratezza
2008 Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena
Realizzazione di un resistore campione da 10 kΩ di elevata accuratezza
2008 Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena
The combined use of a gas-controlled heat pipe and a copper point to improve the calibration of thermocouples up to 1100 °C
2008 Astrua, Milena; Iacomini, Luigi; Battuello, Mauro
A measurement setup to calibrate picoammeters in dc current in the range 100 pA ÷100 nA
2008 Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena
On the Use of the Co-C Fixed Point for Calibration of Pt/Pd Thermocouples
2008 Astrua, Milena; Battuello, Mauro; Girard, Ferruccio
A temperature variable high accuracy 10 kΩ resistor
2009 Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena
Validation of a novel technique for the measurement of the refractive index of a prism by means of interlaboratory comparison
2009 Pisani, Marco; Astrua, Milena
Prism refractive index measurement at INRiM
2009 Astrua, Milena; Pisani, Marco
The new INRiM nanoangle generator
2009 Pisani, Marco; Astrua, Milena
A 100 MΩ step hamon guarded network to improve the traceability level of high resistance up to 1GΩ
2009 Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena
| Citazione | Data di pubblicazione | Autori | File |
|---|---|---|---|
| Construction and investigation of six Pt/Pd thermocouples to be used as secondary standards / Astrua, Milena; Battuello, Mauro; Dematteis, R; Mangano, A.. - 1:(2005), pp. 465-470. ( 9TH INTERNATIONAL SYMPOSIUM ON TEMPERATURE AND THERMAL MEASUREMENTS IN INDUSTRY AND SCIENCE Cavtat - Dubrovnik 22-25 June 2004). | 2005 | ASTRUA, MILENABATTUELLO, MAURO + | - |
| Facility for the calibration of Pt/Pd thermocouples in the temperature range from 960 °C to 1500 °C / Astrua, Milena; Battuello, Mauro; Girard, Ferruccio. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - 17:(2006), pp. 2186-2190. [10.1088/0957-0233/17/8/018] | 2006 | ASTRUA, MILENABATTUELLO, MAUROGIRARD, FERRUCCIO | - |
| Angle amplification for nanoradian measurements / Pisani, Marco; Astrua, Milena. - In: APPLIED OPTICS. - ISSN 1559-128X. - 45:8(2006), pp. 1725-1729. | 2006 | PISANI, MARCOASTRUA, MILENA | angle amplification.pdf |
| Statistical techniques for assessing the agreement between two instruments / Ichim, D; Pennecchi, FRANCESCA ROMANA; Pisani, Marco; Astrua, Milena. - In: METROLOGIA. - ISSN 0026-1394. - 44:(2007), pp. 385-392. | 2007 | PENNECCHI, FRANCESCA ROMANAPISANI, MARCOASTRUA, MILENA + | - |
| Calibrazione di picoamperometri in corrente continua nel range 100 pA ÷100nA mediante uso di reti Hamon / Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena; Gasparotto, E.. - CD-ROM:(2007), pp. 41-42. ( XXIV CONGRESSO ANNUALE DEL GRUPPO NAZIONALE DI COORDINAMENTO “MISURE ELETTRICHE ED ELETTRONICHE” GME TORINO SETTEMBRE 2007.). | 2007 | CAPRA, PIER PAOLOGALLIANA, FLAVIOASTRUA, MILENAE. GASPAROTTO | - |
| Use of a 100 MΩ step HAMON resistor for calibration of pico-ammeters in dc current in the range 100 pA ÷ 100 nA / Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena; Gasparotto, E.. - (2007), pp. cd rom-cdrom. ( 15th IMEKO TC4 Symposium on Novelties in Electrical Measurements 1st IMEKO TC19 Symposium on Measure IASI (ROMANIA) 18 –22 September 2007). | 2007 | CAPRA, PIER PAOLOGALLIANA, FLAVIOASTRUA, MILENAE. GASPAROTTO | - |
| A 100 MΩ STEP HAMON GUARDED NETWORK TO IMPROVE THE TRACEABILITY LEVEL OF HIGH RESISTANCE UP TO 1GΩ / Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena. - CD-ROM:(2007), pp. 41-42. ( 3th International Metrology Congress, “Metrologie 2007 LILLE Giugno 2007). | 2007 | CAPRA, PIER PAOLOGALLIANA, FLAVIOASTRUA, MILENA | - |
| Sub-nanoradian angle measurements / Pisani, Marco; Astrua, Milena. - (2007), pp. 8-11. ( NanoMetrology 2007 – Metrology for Nanotechnology Torino 2007). | 2007 | PISANI, MARCOASTRUA, MILENA | - |
| A temperature variable high accuracy 10 kΩ resistor / Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena. - (2008), pp. 150-154. ( 16th IMEKO TC4 Symp. Expl. New Frontiers of Instrument. and Meth. for Elec and Electr. Meas 13th Wor FIRENZE 22-24 SEPTEMBER 2008). | 2008 | CAPRA, PIER PAOLOCASSIAGO, CRISTINAGALLIANA, FLAVIOASTRUA, MILENA | - |
| Facility for the measurement of the refractive index of glass prism / Astrua, Milena. - (2008). | 2008 | ASTRUA, MILENA | - |
| “Realizzazione di un resistore campione da 10 kΩ di elevata accuratezza / Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena. - CD-ROM:(2008), pp. 41-42. ( XXV CONGRESSO ANNUALE DEL GRUPPO NAZIONALE DI COORDINAMENTO “MISURE ELETTRICHE ED ELETTRONICHE” GMEE ROMA 12÷13 SETTEMBRE 2008.). | 2008 | CAPRA, PIER PAOLOCASSIAGO, CRISTINAGALLIANA, FLAVIOASTRUA, MILENA | - |
| Realizzazione di un resistore campione da 10 kΩ di elevata accuratezza / Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena. - (2008), pp. 53-54. ( XXV Congresso Nazionale del Gruppo di Coordinamento Misure Elettriche ed Elettroniche Roma, Italy 7-10/09/2008). | 2008 | CAPRA, PIER PAOLOCASSIAGO, CRISTINAGALLIANA, FLAVIOASTRUA, MILENA | - |
| The combined use of a gas-controlled heat pipe and a copper point to improve the calibration of thermocouples up to 1100 °C / Astrua, Milena; Iacomini, Luigi; Battuello, Mauro. - In: INTERNATIONAL JOURNAL OF THERMOPHYSICS. - ISSN 0195-928X. - 29:(2008), pp. 1838-1847. | 2008 | ASTRUA, MILENAIACOMINI, LUIGIBATTUELLO, MAURO | - |
| A measurement setup to calibrate picoammeters in dc current in the range 100 pA ÷100 nA / Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena. - CD-ROM:(2008), pp. 41-42. ( Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on Broomfield (COLORADO) 8-13 June 2008) [10.1109/CPEM.2008.4574911]. | 2008 | CAPRA, PIER PAOLOGALLIANA, FLAVIOASTRUA, MILENA | - |
| On the Use of the Co-C Fixed Point for Calibration of Pt/Pd Thermocouples / Astrua, Milena; Battuello, Mauro; Girard, Ferruccio. - In: INTERNATIONAL JOURNAL OF THERMOPHYSICS. - ISSN 0195-928X. - 29:(2008), pp. 190-198. [10.1007/s10765-007-0336-2] | 2008 | ASTRUA, MILENABATTUELLO, MAUROGIRARD, FERRUCCIO | - |
| A temperature variable high accuracy 10 kΩ resistor / Capra, PIER PAOLO; Cassiago, Cristina; Galliana, Flavio; Astrua, Milena. - In: METROLOGY AND MEASUREMENT SYSTEMS. - ISSN 2080-9050. - 61:(2009), pp. 183-191. | 2009 | CAPRA, PIER PAOLOCASSIAGO, CRISTINAGALLIANA, FLAVIOASTRUA, MILENA | - |
| Validation of a novel technique for the measurement of the refractive index of a prism by means of interlaboratory comparison / Pisani, Marco; Astrua, Milena. - In: MEASUREMENT. - ISSN 0263-2241. - 42:(2009), pp. 1546-1549. | 2009 | PISANI, MARCOASTRUA, MILENA | - |
| Prism refractive index measurement at INRiM / Astrua, Milena; Pisani, Marco. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - 20:(2009), pp. 095305-095311. | 2009 | ASTRUA, MILENAPISANI, MARCO | - |
| The new INRiM nanoangle generator / Pisani, Marco; Astrua, Milena. - In: METROLOGIA. - ISSN 0026-1394. - 46:(2009), pp. 674-681. | 2009 | PISANI, MARCOASTRUA, MILENA | - |
| A 100 MΩ step hamon guarded network to improve the traceability level of high resistance up to 1GΩ / Capra, PIER PAOLO; Galliana, Flavio; Astrua, Milena. - (2009), pp. 525-533. | 2009 | CAPRA, PIER PAOLOGALLIANA, FLAVIOASTRUA, MILENA | - |
Legenda icone
- file ad accesso aperto
- file disponibili sulla rete interna
- file disponibili agli utenti autorizzati
- file disponibili solo agli amministratori
- file sotto embargo
- nessun file disponibile