SAR assessment is a major concern in MRI. The energy absorbed by tissues increases quadratically with the static magnetic field; therefore, ultra-high field (>= 7 T) systems require careful dosimetry to exploit their potential. The objectives are to validate the use of electric-field probe for SAR assessment for high-field MRI, and to study the advantages and drawbacks of E-field measurements. The experiments were performed at 7 and 11.7 T on preclinical systems in a phantom with calibrated dielectric properties. Absolute values of the E-field were measured according to position inside a birdcage coil and electrical conductivity, local temperature increase were simultaneously evaluated with operating RF frequency, as well as the re-positioning precision through five repetitive measurements. Results yielded a 14.8 +/- 0.36 W/kg SAR near the coil's capacitors compared to 6.8 +/- 0.17 W/kg estimated at the center of the coil. The temperature rise was nevertheless higher in the center likely due to heat transfer effects. The SAR measured in similar conditions was 5.2 times higher at 11.7 T than at 7 T. The probes induced no visible artefact, and the test to estimate the reproducibility of positioning the sensors granted a low 2.3 % coefficient of variation. Measuring both the cause (E-field) and the effect (temperature rise) yielded different information, both useful in the context of EM simulation validation.

Electric field measurements in preclinical MRI at 11.7 T and 7 T for experimental SAR comparison / Nobre, Paul; Gaborit, Gwenaël; Troia, Adriano; Zanovello, Umberto; Duvillaret, Lionel; Beuf, Olivier. - In: JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS. - ISSN 0304-8853. - 593:(2024). [10.1016/j.jmmm.2024.171818]

Electric field measurements in preclinical MRI at 11.7 T and 7 T for experimental SAR comparison

Troia, Adriano;Zanovello, Umberto;
2024

Abstract

SAR assessment is a major concern in MRI. The energy absorbed by tissues increases quadratically with the static magnetic field; therefore, ultra-high field (>= 7 T) systems require careful dosimetry to exploit their potential. The objectives are to validate the use of electric-field probe for SAR assessment for high-field MRI, and to study the advantages and drawbacks of E-field measurements. The experiments were performed at 7 and 11.7 T on preclinical systems in a phantom with calibrated dielectric properties. Absolute values of the E-field were measured according to position inside a birdcage coil and electrical conductivity, local temperature increase were simultaneously evaluated with operating RF frequency, as well as the re-positioning precision through five repetitive measurements. Results yielded a 14.8 +/- 0.36 W/kg SAR near the coil's capacitors compared to 6.8 +/- 0.17 W/kg estimated at the center of the coil. The temperature rise was nevertheless higher in the center likely due to heat transfer effects. The SAR measured in similar conditions was 5.2 times higher at 11.7 T than at 7 T. The probes induced no visible artefact, and the test to estimate the reproducibility of positioning the sensors granted a low 2.3 % coefficient of variation. Measuring both the cause (E-field) and the effect (temperature rise) yielded different information, both useful in the context of EM simulation validation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/82179
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact