The PTOLEMY project is devoted to directly detect the cosmic neutrino background. A key point for the project success is the development of a device which is capable of detecting electrons with an energy resolution lower than 0.05 eV. Microcalorimeters based on transition-edge sensors are among the best candidates since they already reach 0.11 eV of energy resolution for telecomm photons. To further improve the energy resolution, while maintaining a suitable saturation energy, it is necessary to reduce the transition temperature. This could be achieved by proximity effect of a normal-superconducting bilayer. To this aim, TiAu very thin films are under development to demonstrate the feasibility of reaching 0.05 eV energy resolution for light pulses of few eV. Thanks to the high electron stopping power of metals, the penetration depth of low energy incident electrons is limited to few nanometers and, with respect to visible light, we expect a high detection efficiency, while keeping similar dark counts and energy resolution.

TES Microcalorimeters for PTOLEMY / Rajteri, M.; Biasotti, M.; Faverzani, M.; Ferri, E.; Filippo, R.; Gatti, F.; Giachero, A.; Monticone, E.; Nucciotti, A.; Puiu, A.. - In: JOURNAL OF LOW TEMPERATURE PHYSICS. - ISSN 0022-2291. - 199:(2020), pp. 138-142. [10.1007/s10909-019-02271-x]

TES Microcalorimeters for PTOLEMY

Rajteri, M.
;
Filippo, R.;Monticone, E.;
2020

Abstract

The PTOLEMY project is devoted to directly detect the cosmic neutrino background. A key point for the project success is the development of a device which is capable of detecting electrons with an energy resolution lower than 0.05 eV. Microcalorimeters based on transition-edge sensors are among the best candidates since they already reach 0.11 eV of energy resolution for telecomm photons. To further improve the energy resolution, while maintaining a suitable saturation energy, it is necessary to reduce the transition temperature. This could be achieved by proximity effect of a normal-superconducting bilayer. To this aim, TiAu very thin films are under development to demonstrate the feasibility of reaching 0.05 eV energy resolution for light pulses of few eV. Thanks to the high electron stopping power of metals, the penetration depth of low energy incident electrons is limited to few nanometers and, with respect to visible light, we expect a high detection efficiency, while keeping similar dark counts and energy resolution.
File in questo prodotto:
File Dimensione Formato  
Paper TES for PTOLEMY v2_revised_iris.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 552.32 kB
Formato Adobe PDF
552.32 kB Adobe PDF Visualizza/Apri
s10909-019-02271-x.pdf

non disponibili

Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 889.41 kB
Formato Adobe PDF
889.41 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/68373
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact