We report speed of sound measurements in helium at 273.16 K and at eight temperatures in the range between 236 K and 430 K. These results determine the difference (T  −  T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). The uncertainty of our measurements of (T  −  T 90) spans between a minimum of 0.25 mK near 247 K and a maximum of 0.89 mK at the freezing point of indium (429.75 K) with comparable contributions from the uncertainty of our acoustic determination of T and from the uncertainty of our laboratory realization of ITS-90. On the overlapping temperature ranges these results are consistent with other recent acoustic determinations of (T  −  T 90). We also present evidence that (T  −  T 90) can be determined with comparably small uncertainties by the alternative, time-saving procedure of measuring the speed-of-sound in helium using only a single, judiciously-chosen, pressure on each isotherm.

Determination of the thermodynamic temperature between 236 K and 430 K from speed of sound measurements in helium / Gavioso, R.; Madonna Ripa, D.; Steur, P.; Dematteis, R.; Imbraguglio, D.. - In: METROLOGIA. - ISSN 0026-1394. - 56:4(2019), p. 045006. [10.1088/1681-7575/ab29a2]

Determination of the thermodynamic temperature between 236 K and 430 K from speed of sound measurements in helium

R. Gavioso
;
D. Madonna Ripa;P. Steur;R. Dematteis;D. Imbraguglio
2019

Abstract

We report speed of sound measurements in helium at 273.16 K and at eight temperatures in the range between 236 K and 430 K. These results determine the difference (T  −  T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). The uncertainty of our measurements of (T  −  T 90) spans between a minimum of 0.25 mK near 247 K and a maximum of 0.89 mK at the freezing point of indium (429.75 K) with comparable contributions from the uncertainty of our acoustic determination of T and from the uncertainty of our laboratory realization of ITS-90. On the overlapping temperature ranges these results are consistent with other recent acoustic determinations of (T  −  T 90). We also present evidence that (T  −  T 90) can be determined with comparably small uncertainties by the alternative, time-saving procedure of measuring the speed-of-sound in helium using only a single, judiciously-chosen, pressure on each isotherm.
File in questo prodotto:
File Dimensione Formato  
Gavioso_2019_Metrologia_56_045006.pdf

accesso aperto

Tipologia: final published article (publisher’s version)
Licenza: Creative Commons
Dimensione 2.9 MB
Formato Adobe PDF
2.9 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/61249
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 25
social impact