An accurate measurement of saturation vapor pressure of supercooled water is a strong challenge in metrology, mainly due to difficulties concerning keeping water at a liquid state at temperatures well below the melting point; thus few experimental data covering limited temperature ranges (down to about 253 K) are reported in literature. For this reason, an investigation of the water vapor – supercooled water equilibrium along the saturation line is carried out at Istituto Nazionale di Ricerca Metrologica (INRIM). Measurements cover the temperature range from 261.26 K to 273.25 K, corresponding to a saturation vapor pressure from about 244 Pa to 611 Pa. The experimental apparatus includes a borosilicate glass sample cell, kept in a liquid bath at a constant temperature with millikelvin stability and connected to a manifold where the pressure is measured using a capacitive diaphragm pressure gauge. In this work, the water sample preparation, the measuring method and measurement corrections are reported; moreover, a comparison between experimental and literature data is conducted along with the most used vapor pressure formulations. Measurement results are discussed and uncertainty sources estimated. The resulting expanded relative uncertainty (k = 2) varies from 0.085% at 261.26 K to 0.039% at 273.25 K.

Vapor pressure measurements over supercooled water in the temperature range from −10 1 °C to +10 −2 °C / Beltramino, G.; Rosso, L.; Smorgon, D.; Fernicola, V.. - In: JOURNAL OF CHEMICAL THERMODYNAMICS. - ISSN 0021-9614. - 105:(2017), pp. 159-164. [10.1016/j.jct.2016.10.003]

Vapor pressure measurements over supercooled water in the temperature range from −10 1 °C to +10 −2 °C

Beltramino, G.
;
Rosso, L.;Smorgon, D.;Fernicola, V.
2017

Abstract

An accurate measurement of saturation vapor pressure of supercooled water is a strong challenge in metrology, mainly due to difficulties concerning keeping water at a liquid state at temperatures well below the melting point; thus few experimental data covering limited temperature ranges (down to about 253 K) are reported in literature. For this reason, an investigation of the water vapor – supercooled water equilibrium along the saturation line is carried out at Istituto Nazionale di Ricerca Metrologica (INRIM). Measurements cover the temperature range from 261.26 K to 273.25 K, corresponding to a saturation vapor pressure from about 244 Pa to 611 Pa. The experimental apparatus includes a borosilicate glass sample cell, kept in a liquid bath at a constant temperature with millikelvin stability and connected to a manifold where the pressure is measured using a capacitive diaphragm pressure gauge. In this work, the water sample preparation, the measuring method and measurement corrections are reported; moreover, a comparison between experimental and literature data is conducted along with the most used vapor pressure formulations. Measurement results are discussed and uncertainty sources estimated. The resulting expanded relative uncertainty (k = 2) varies from 0.085% at 261.26 K to 0.039% at 273.25 K.
File in questo prodotto:
File Dimensione Formato  
Paper_water vapor measurements over supercooled water_clean.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Creative Commons
Dimensione 354.81 kB
Formato Adobe PDF
354.81 kB Adobe PDF Visualizza/Apri
1-s2.0-S0021961416303032-main.pdf

non disponibili

Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 657.85 kB
Formato Adobe PDF
657.85 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/57192
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact