The use of new silicon single crystals highly enriched in (28)Si recently produced for the upcoming redetermination of the Avogadro constant requires knowledge of their molar masses. The isotopic composition data are collected independently in different laboratories but all using the virtual element technique with multicollector inductively coupled plasma mass spectrometers. In this framework, the comparison of the results with an independent measurement of the amount of at least one of the depleted isotopes is useful to limit hidden systematic errors. To this aim, the (30)Si mole fraction of a sample of the new material was measured using a relative measurement protocol based on instrumental neutron activation analysis. The protocol is similar to that previously applied with the AVO28 silicon material used for the last determination of the Avogadro constant value with the exception that unknown and standard samples are not coirradiated. The x((30)Si) = 5.701 × 10(-7) mol mol(-1) estimate is close to the expected one and is given with a standard uncertainty of 8.8 × 10(-9) mol mol(-1). This value, if adopted, gives a contribution to the relative standard uncertainty of the Avogadro constant of 6.3 × 10(-10).
Measurement of the (30)Si Mole Fraction in the New Avogadro Silicon Material by Neutron Activation and High-Resolution γ-Spectrometry / Di Luzio, Marco; Stopic, Attila; D'Agostino, Giancarlo; Bennett, John W; Mana, Giovanni; Oddone, Massimo; Pramann, Axel. - In: ANALYTICAL CHEMISTRY. - ISSN 0003-2700. - 89:12(2017), pp. 6726-6730-6730. [10.1021/acs.analchem.7b00963]
Measurement of the (30)Si Mole Fraction in the New Avogadro Silicon Material by Neutron Activation and High-Resolution γ-Spectrometry
Di Luzio, Marco;D'AGOSTINO, GIANCARLO
;MANA, GIOVANNI;
2017
Abstract
The use of new silicon single crystals highly enriched in (28)Si recently produced for the upcoming redetermination of the Avogadro constant requires knowledge of their molar masses. The isotopic composition data are collected independently in different laboratories but all using the virtual element technique with multicollector inductively coupled plasma mass spectrometers. In this framework, the comparison of the results with an independent measurement of the amount of at least one of the depleted isotopes is useful to limit hidden systematic errors. To this aim, the (30)Si mole fraction of a sample of the new material was measured using a relative measurement protocol based on instrumental neutron activation analysis. The protocol is similar to that previously applied with the AVO28 silicon material used for the last determination of the Avogadro constant value with the exception that unknown and standard samples are not coirradiated. The x((30)Si) = 5.701 × 10(-7) mol mol(-1) estimate is close to the expected one and is given with a standard uncertainty of 8.8 × 10(-9) mol mol(-1). This value, if adopted, gives a contribution to the relative standard uncertainty of the Avogadro constant of 6.3 × 10(-10).File | Dimensione | Formato | |
---|---|---|---|
di luzio et al rev.pdf
accesso aperto
Tipologia:
accepted manuscript (author’s post-print)
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
237.41 kB
Formato
Adobe PDF
|
237.41 kB | Adobe PDF | Visualizza/Apri |
2017 di luzio x30Si.pdf
non disponibili
Tipologia:
final published article (publisher’s version)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.17 MB
Formato
Adobe PDF
|
1.17 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.