The use of new silicon single crystals highly enriched in (28)Si recently produced for the upcoming redetermination of the Avogadro constant requires knowledge of their molar masses. The isotopic composition data are collected independently in different laboratories but all using the virtual element technique with multicollector inductively coupled plasma mass spectrometers. In this framework, the comparison of the results with an independent measurement of the amount of at least one of the depleted isotopes is useful to limit hidden systematic errors. To this aim, the (30)Si mole fraction of a sample of the new material was measured using a relative measurement protocol based on instrumental neutron activation analysis. The protocol is similar to that previously applied with the AVO28 silicon material used for the last determination of the Avogadro constant value with the exception that unknown and standard samples are not coirradiated. The x((30)Si) = 5.701 × 10(-7) mol mol(-1) estimate is close to the expected one and is given with a standard uncertainty of 8.8 × 10(-9) mol mol(-1). This value, if adopted, gives a contribution to the relative standard uncertainty of the Avogadro constant of 6.3 × 10(-10).

Measurement of the (30)Si Mole Fraction in the New Avogadro Silicon Material by Neutron Activation and High-Resolution γ-Spectrometry / Di Luzio, Marco; Stopic, Attila; D'Agostino, Giancarlo; Bennett, John W; Mana, Giovanni; Oddone, Massimo; Pramann, Axel. - In: ANALYTICAL CHEMISTRY. - ISSN 0003-2700. - 89:12(2017), pp. 6726-6730-6730. [10.1021/acs.analchem.7b00963]

Measurement of the (30)Si Mole Fraction in the New Avogadro Silicon Material by Neutron Activation and High-Resolution γ-Spectrometry

Di Luzio, Marco;D'AGOSTINO, GIANCARLO
;
MANA, GIOVANNI;
2017

Abstract

The use of new silicon single crystals highly enriched in (28)Si recently produced for the upcoming redetermination of the Avogadro constant requires knowledge of their molar masses. The isotopic composition data are collected independently in different laboratories but all using the virtual element technique with multicollector inductively coupled plasma mass spectrometers. In this framework, the comparison of the results with an independent measurement of the amount of at least one of the depleted isotopes is useful to limit hidden systematic errors. To this aim, the (30)Si mole fraction of a sample of the new material was measured using a relative measurement protocol based on instrumental neutron activation analysis. The protocol is similar to that previously applied with the AVO28 silicon material used for the last determination of the Avogadro constant value with the exception that unknown and standard samples are not coirradiated. The x((30)Si) = 5.701 × 10(-7) mol mol(-1) estimate is close to the expected one and is given with a standard uncertainty of 8.8 × 10(-9) mol mol(-1). This value, if adopted, gives a contribution to the relative standard uncertainty of the Avogadro constant of 6.3 × 10(-10).
File in questo prodotto:
File Dimensione Formato  
di luzio et al rev.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 237.41 kB
Formato Adobe PDF
237.41 kB Adobe PDF Visualizza/Apri
2017 di luzio x30Si.pdf

non disponibili

Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/55329
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact