This paper concerns the sensing of dynamic force/stress by means of a measuring system based on the use of an Fe-Ga sample (Galfenol) coupled to a magnetic circuit. The study is focused on the measurement of the effective magnetic field, detected at the rod specimen surface, and its variation DeltaHeff under time-dependent applied sinusoidal stress DeltaSigma oscillating at frequencies between 5 Hz and 20 Hz at different values of applied bias field Sigmabias (2.5 kA/m < Sigmabias < 27 kA/m). For the considered frequency and Hbias range, the measured DeltaHeff tends to linearly depend on DeltaSigma in contrast with the corresponding induction variation behavior (DeltaB - DeltaSigma), where hysteresis effects appear. With DeltaSigma in the range ± 15 MPa we obtain 0.06 MPa resolution in the determination of the alternating stress DeltaSigma, a result pointing to the effectiveness and sensitivity of this Galfenol-based method for detection and measurement of time-dependent stresses
Sensing dynamic forces by Fe-Ga in compression / Zucca, Mauro; Mei, Pasquale; Ferrara, Enzo; Fiorillo, Fausto. - In: IEEE TRANSACTIONS ON MAGNETICS. - ISSN 0018-9464. - (2017), pp. 1-4. [10.1109/TMAG.2017.2701859]
Sensing dynamic forces by Fe-Ga in compression
ZUCCA, MAURO;FERRARA, ENZO;
2017
Abstract
This paper concerns the sensing of dynamic force/stress by means of a measuring system based on the use of an Fe-Ga sample (Galfenol) coupled to a magnetic circuit. The study is focused on the measurement of the effective magnetic field, detected at the rod specimen surface, and its variation DeltaHeff under time-dependent applied sinusoidal stress DeltaSigma oscillating at frequencies between 5 Hz and 20 Hz at different values of applied bias field Sigmabias (2.5 kA/m < Sigmabias < 27 kA/m). For the considered frequency and Hbias range, the measured DeltaHeff tends to linearly depend on DeltaSigma in contrast with the corresponding induction variation behavior (DeltaB - DeltaSigma), where hysteresis effects appear. With DeltaSigma in the range ± 15 MPa we obtain 0.06 MPa resolution in the determination of the alternating stress DeltaSigma, a result pointing to the effectiveness and sensitivity of this Galfenol-based method for detection and measurement of time-dependent stressesFile | Dimensione | Formato | |
---|---|---|---|
TMAG2701859_Fe-Ga compression postprint (1).pdf
solo utenti autorizzati
Descrizione: Articolo principale
Tipologia:
accepted manuscript (author’s post-print)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
680.28 kB
Formato
Adobe PDF
|
680.28 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.