Volatile Organic Compounds (VOC) at trace level are common indicators for climate change and ambient air quality. The calibration of detection systems at trace level needs VOC mixtures at nmol/mol level with 5% uncertainty, the dynamic preparation can fulfil it. A source of uncertainty for dynamic generation is the stability of the VOC molar fraction averaged on the sampling time. A general method for the calculation of the relevance of the stability contribution to the total uncertainty is here proposed. VOC molar fraction is here considered as a composed quantity. Threshold values for stability contribution were set to consider it either as negligible and relevant. The stability of the operative quantities of a device, for the dynamic preparation of accurate VOC reference mixtures, was measured at the working conditions by the Allan deviation algorithm. Stabilities of operative quantities were composed to calculate the VOC molar fraction stability and their contribution to total uncertainty of VOC molar fraction. The stability of the air inlet pressure gave the main stability contribution. The stability contribution to the total uncertainty resulted to be negligible for observation times below 60 min for VOC molar fraction uncertainty of 2% at 30 nmol/mol level.

Molar fraction stability in dynamic preparation of reference trace gas mixtures / Demichelis, Alessia; Sassi, Guido; Lecuna, Maricarmen; Sassi, MARIA PAOLA. - In: IET SCIENCE, MEASUREMENT & TECHNOLOGY. - ISSN 1751-8822. - 10:5(2016), pp. 414-419. [10.1049/iet-smt.2015.0051]

Molar fraction stability in dynamic preparation of reference trace gas mixtures

SASSI, MARIA PAOLA
2016

Abstract

Volatile Organic Compounds (VOC) at trace level are common indicators for climate change and ambient air quality. The calibration of detection systems at trace level needs VOC mixtures at nmol/mol level with 5% uncertainty, the dynamic preparation can fulfil it. A source of uncertainty for dynamic generation is the stability of the VOC molar fraction averaged on the sampling time. A general method for the calculation of the relevance of the stability contribution to the total uncertainty is here proposed. VOC molar fraction is here considered as a composed quantity. Threshold values for stability contribution were set to consider it either as negligible and relevant. The stability of the operative quantities of a device, for the dynamic preparation of accurate VOC reference mixtures, was measured at the working conditions by the Allan deviation algorithm. Stabilities of operative quantities were composed to calculate the VOC molar fraction stability and their contribution to total uncertainty of VOC molar fraction. The stability of the air inlet pressure gave the main stability contribution. The stability contribution to the total uncertainty resulted to be negligible for observation times below 60 min for VOC molar fraction uncertainty of 2% at 30 nmol/mol level.
File in questo prodotto:
File Dimensione Formato  
07522697(1).pdf

solo utenti autorizzati

Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 355.54 kB
Formato Adobe PDF
355.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/54706
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact