The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour / Hioki, Akiharu; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shinichi; Kotzeva, Boriana; Kakoulides, Elias; Sxoina, Vasiliki; Fung, W. H; Choi, Y. Y; Yau, H. P; Tsoi, Y. T; Lee, C. L; Kong, M. F; Shin, Richard; Juan, Wang; Yee, Ng Sin; Uribe, Christian; Marques Rodrigues, Janaína; Caciano de Sena, Rodrigo; Silva Dutra, Emily; Bergamaschi, Luigi; Giordani, Laura; D'Agostino, Giancarlo; Valiente, Liliana; Horvat, Milena; Jacimovic, Radojko; Oduor Okumu, Tom; Kang'Iri, Jacqueline; Owiti Orwa, Tabitha; Chao, Wei; Jingbo, Chao; Taebunpakul, Sutthinun; Yafa, Charun; Kaewkhomdee, Nattikarn; Chailap, Benjamat; Pharat, Yanee; Phukphattanachai, Pranee; C. Turk, Gregory; Long, Stephen; Murphy, K. E; Davis, Clay; Ellisor, Michael; Merrick, Jeffrey; White, Ian; Saxby, David; Linsky, S. M; Barzev, A; Botha, A.. - In: METROLOGIA. - ISSN 0026-1394. - 52:1A(2015), pp. 08005-08005. [10.1088/0026-1394/52/1A/08005]
Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour
BERGAMASCHI, LUIGI;D'AGOSTINO, GIANCARLO;
2015
Abstract
The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).File | Dimensione | Formato | |
---|---|---|---|
CCQM-K108.pdf
accesso aperto
Tipologia:
final published article (publisher’s version)
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
603.58 kB
Formato
Adobe PDF
|
603.58 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.