A simple, well-established (although in applications different from electromagnetic compatibility), amenable to direct interpretation, and inexpensive method for the time-domain characterization of the measurement systems used for the calibration of the standard impulse generators for immunity tests is presented. The validity and general applicability of the method is demonstrated through an extensive experimental investigation.

Time-Domain Characterization of the Surge, EFT/Burst, and ESD Measurement Systems / Carobbi, C. F. M.; Bonci, A; Stellini, M; Borsero, Michele. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - (2013), pp. 1-7. [10.1109/TIM.2013.2239017]

Time-Domain Characterization of the Surge, EFT/Burst, and ESD Measurement Systems

BORSERO, MICHELE
2013

Abstract

A simple, well-established (although in applications different from electromagnetic compatibility), amenable to direct interpretation, and inexpensive method for the time-domain characterization of the measurement systems used for the calibration of the standard impulse generators for immunity tests is presented. The validity and general applicability of the method is demonstrated through an extensive experimental investigation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/32459
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 16
social impact