In this paper we report the theoretical and experimental characterization of a pulsed optically pumped vapor-cell frequency standard based on the detection of the free-induction decay microwave signal. The features that make this standard similar to a pulsed passive maser are presented. In order to predict and optimize the frequency stability, thermal and shot noise sources are analyzed, as well as the conversions of the laser and microwave fluctuations into the output frequency. The experimental results obtained with a clock prototype based on 87Rb in buffer gas are compared with the theoretical predictions, showing the practical possibility to implement a frequency standard limited in the medium term only by thermal drift. The achieved frequency stability is σy(τ)=1.2×10−12τ−1∕2 for measurement times up to τ≈105 s. It represents one of the best results reported in literature for gas cell frequency standards and is compliant with the pre...

Physics characterization and frequency stability of the pulsed rubidium maser / Godone, A; Micalizio, Salvatore; Levi, Filippo; Calosso, CLAUDIO ELIGIO. - In: PHYSICAL REVIEW A. - ISSN 1050-2947. - 74:(2006), pp. 043401-1-043401-12. [10.1103/PhysRevA.74.043401]

Physics characterization and frequency stability of the pulsed rubidium maser

MICALIZIO, SALVATORE;LEVI, FILIPPO;CALOSSO, CLAUDIO ELIGIO
2006

Abstract

In this paper we report the theoretical and experimental characterization of a pulsed optically pumped vapor-cell frequency standard based on the detection of the free-induction decay microwave signal. The features that make this standard similar to a pulsed passive maser are presented. In order to predict and optimize the frequency stability, thermal and shot noise sources are analyzed, as well as the conversions of the laser and microwave fluctuations into the output frequency. The experimental results obtained with a clock prototype based on 87Rb in buffer gas are compared with the theoretical predictions, showing the practical possibility to implement a frequency standard limited in the medium term only by thermal drift. The achieved frequency stability is σy(τ)=1.2×10−12τ−1∕2 for measurement times up to τ≈105 s. It represents one of the best results reported in literature for gas cell frequency standards and is compliant with the pre...
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/31664
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 49
social impact