A general approach to magnetic losses in Soft Magnetic Composites (SMC) is discussed. It is applied to exciting conditions typical of applications, where the induction waveform is most frequently non-sinusoidal. The standard predicting approach, based on the Statistical Theory of Losses (STL) and the related concept of loss separation, is extended to the case of granular heterogeneous materials. As a starting point, the classical loss component is calculated, taking into account that in small enough samples the measured loss is independent of the specimen cross-sectional area, because of negligible grain-to-grain (macroscopic) eddy currents. The loss separation is then performed under the conventional sinusoidal induction regime and the STL is used to identify a limited set of parameters, associated with the prediction of the excess loss, by which the energy loss under distorted induction can be predicted. Significant predicting examples are provided, regarding two different SMCs, where the induction waveform is either triangular or distorted by introduction of a third harmonic component.

Characterization and prediction of magnetic losses in Soft Magnetic Composites under distorted induction waveform / O., de la Barrière; Appino, Carlo; F., Fiorillo; C., Ragusa; M., Lecrivain; L., Rocchino; H., Ben Ahmed; M., Gabsi; F., Mazaleyrat; M., Lo Bue. - In: IEEE TRANSACTIONS ON MAGNETICS. - ISSN 0018-9464. - 49:4(2013), pp. 1318-1326.

Characterization and prediction of magnetic losses in Soft Magnetic Composites under distorted induction waveform

APPINO, CARLO;
2013

Abstract

A general approach to magnetic losses in Soft Magnetic Composites (SMC) is discussed. It is applied to exciting conditions typical of applications, where the induction waveform is most frequently non-sinusoidal. The standard predicting approach, based on the Statistical Theory of Losses (STL) and the related concept of loss separation, is extended to the case of granular heterogeneous materials. As a starting point, the classical loss component is calculated, taking into account that in small enough samples the measured loss is independent of the specimen cross-sectional area, because of negligible grain-to-grain (macroscopic) eddy currents. The loss separation is then performed under the conventional sinusoidal induction regime and the STL is used to identify a limited set of parameters, associated with the prediction of the excess loss, by which the energy loss under distorted induction can be predicted. Significant predicting examples are provided, regarding two different SMCs, where the induction waveform is either triangular or distorted by introduction of a third harmonic component.
File in questo prodotto:
File Dimensione Formato  
2013 49 BarAppFioRagLecRocBenGabMazLob.pdf

non disponibili

Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.15 MB
Formato Adobe PDF
2.15 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/31647
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 50
social impact