The Primary Standard Radiation Thermometry Labs of INRiM has recently adopted two high quality commercial type radiation thermometers to be used as primary and transfer standard instruments, respectively. The first instrument will be employed for the realization of the International Temperature Scale (ITS-90) in the temperature range between 960 °C and 2800 °C and the second device for the approximation and dissemination of traceability in the temperature range from 420 °C and 2100 °C. This technical report describes the measurement processes that led to the primary calibration of both thermometers. The first one according to the requirements allowed for the implementation of the ITS-90 and the second according to the fixed-points method (Zn, Al, Ag and Cu) as well as the results obtained in the direct comparison of the two radiance scales realized in the temperature range between 960 °C and 2100 °C.

Realizzazione e confronto di scale di radianza a 650 nm e 900 nm tra 960 °C e 2100 °C con i termometri: Chino IR-RST65H e Chino IR-RST90H / Girard, F.; Florio, M.. - (2023).

Realizzazione e confronto di scale di radianza a 650 nm e 900 nm tra 960 °C e 2100 °C con i termometri: Chino IR-RST65H e Chino IR-RST90H.

F. Girard
Writing – Original Draft Preparation
;
M. Florio
2023

Abstract

The Primary Standard Radiation Thermometry Labs of INRiM has recently adopted two high quality commercial type radiation thermometers to be used as primary and transfer standard instruments, respectively. The first instrument will be employed for the realization of the International Temperature Scale (ITS-90) in the temperature range between 960 °C and 2800 °C and the second device for the approximation and dissemination of traceability in the temperature range from 420 °C and 2100 °C. This technical report describes the measurement processes that led to the primary calibration of both thermometers. The first one according to the requirements allowed for the implementation of the ITS-90 and the second according to the fixed-points method (Zn, Al, Ag and Cu) as well as the results obtained in the direct comparison of the two radiance scales realized in the temperature range between 960 °C and 2100 °C.
2023
13
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/79299
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact