Usually, in biomedical optics, the average photon fluence rate, evaluated in a subvolume of a propagating medium, is obtained by Monte Carlo simulations by calculating the power deposited by photons absorbed in the subvolume. We propose an alternative method based on evaluating the average path length traveled by all photons injected within the subvolume. Application examples are given. This method also works for a zero absorption coefficient and for a nonconstant spatial distribution of the absorption coefficient within the subvolume. The proposed approach is a re-visitation of a well-known method applied to nuclear and radiation physics. The results obtained show that a potential advantage of the proposed method is that it can improve the convergence of Monte Carlo simulations. Indeed, when calculating the fluence in a region of interest with the proposed method, all photons passing through the region are considered. Whereas with the traditional approach, only absorbed" photons are considered. In the latter case, this can produce a poorer Monte Carlo statistic for the same number of photons launched.

Relation between fluence rate and mean photons pathlengths: an alternative option for Monte Carlo-based-calculations of fluence / Tommasi, Federico; Sassaroli, Angelo; Fini, Lorenzo; Cavalieri, Stefano; Pini, Ernesto; Pattelli, Lorenzo; Martelli, Fabrizio. - 12628:(2023), p. 90. (Intervento presentato al convegno European Conferences on Biomedical Optics) [10.1117/12.2670936].

Relation between fluence rate and mean photons pathlengths: an alternative option for Monte Carlo-based-calculations of fluence

Pattelli, Lorenzo;
2023

Abstract

Usually, in biomedical optics, the average photon fluence rate, evaluated in a subvolume of a propagating medium, is obtained by Monte Carlo simulations by calculating the power deposited by photons absorbed in the subvolume. We propose an alternative method based on evaluating the average path length traveled by all photons injected within the subvolume. Application examples are given. This method also works for a zero absorption coefficient and for a nonconstant spatial distribution of the absorption coefficient within the subvolume. The proposed approach is a re-visitation of a well-known method applied to nuclear and radiation physics. The results obtained show that a potential advantage of the proposed method is that it can improve the convergence of Monte Carlo simulations. Indeed, when calculating the fluence in a region of interest with the proposed method, all photons passing through the region are considered. Whereas with the traditional approach, only absorbed" photons are considered. In the latter case, this can produce a poorer Monte Carlo statistic for the same number of photons launched.
2023
European Conferences on Biomedical Optics
partially_open
File in questo prodotto:
File Dimensione Formato  
8e40047a-5e21-4e46-998e-d3639499fe2d_submitted_16_06_2023.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Creative Commons
Dimensione 931.49 kB
Formato Adobe PDF
931.49 kB Adobe PDF Visualizza/Apri
126282I.pdf

non disponibili

Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 725.91 kB
Formato Adobe PDF
725.91 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/77539
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact