A method to characterize instruments based on ILMDs (Image Luminance Measuring Device) for applications in road and tunnel lighting installation is presented. In road lighting applications, these devices measure the road surface luminance for controlling smart adaptive road lighting systems. The measurement range is between 0,1 cd m-2 and 3 cd m-2 (CEN, 2015a). In tunnel lighting, the instrument measures the atmospheric luminance, the equivalent veiling luminance and calculates the veiling luminance for controlling the lighting level in the threshold zone of the tunnel. In this case the range of measured luminances is between 100 cd m-2 and 20 kcd m-2. In both cases instruments should have low cost, a great stability and repeatability, and low sensitivity to climatic conditions (CEN, 2015b). Their calibration procedure shall be simple but adequate to application requirements and real operating conditions.

METROLOGICAL CHARACTERIZATION OF ILMD FOR SMART LIGHTING APPLICATIONS / Rossi, G.; Iacomussi, P.; Radis, M.. - (2017). (Intervento presentato al convegno Smarter Lighting for Better Life tenutosi a JEJU COREA DEL SUD nel 23-25 OTTOBRE 2017).

METROLOGICAL CHARACTERIZATION OF ILMD FOR SMART LIGHTING APPLICATIONS

Rossi, G.
;
Iacomussi, P.
;
Radis, M.
2017

Abstract

A method to characterize instruments based on ILMDs (Image Luminance Measuring Device) for applications in road and tunnel lighting installation is presented. In road lighting applications, these devices measure the road surface luminance for controlling smart adaptive road lighting systems. The measurement range is between 0,1 cd m-2 and 3 cd m-2 (CEN, 2015a). In tunnel lighting, the instrument measures the atmospheric luminance, the equivalent veiling luminance and calculates the veiling luminance for controlling the lighting level in the threshold zone of the tunnel. In this case the range of measured luminances is between 100 cd m-2 and 20 kcd m-2. In both cases instruments should have low cost, a great stability and repeatability, and low sensitivity to climatic conditions (CEN, 2015b). Their calibration procedure shall be simple but adequate to application requirements and real operating conditions.
2017
Smarter Lighting for Better Life
23-25 OTTOBRE 2017
JEJU COREA DEL SUD
reserved
File in questo prodotto:
File Dimensione Formato  
METROLOGICAL-CHARACTERIZATION-OF-ILMD-FOR-SMART-LIGHTING-APPLICATIONS.pdf

non disponibili

Tipologia: submitted version (author’s pre-print)
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 189.23 kB
Formato Adobe PDF
189.23 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/57115
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact