This technical report describes the analysis of the results obtained by the ACAE encoded laboratories, participants in the Round Robin Test in the course of 2016, which performed a temperature rise test on a simulacrum of low voltage switch. Each participating laboratory performed measurements of temperature and electrical resistance of the object under test made available by Bticino SpA, circulated to all participating laboratories, and in which were placed the copper bars, instead of the normal structures (contacts mobile and fixed, and related mechanisms), to make it more stable in time. The laboratories have conducted the tests in accordance with the relevant product standard (IEC 60947-2), respecting the requirements of the method for the preparation of the object and both the measuring process. The purpose of the Round Robin test was to capture all the data of the laboratories and to make an analysis and verify the quality assurance of measurements taken, requirement 5.9 of ISO / IEC 17025, as well as bring out critical issues due to technical measures, the object set-up and even the failings inherent in the test method. Based on the results obtained it will also be possible, by the individual laboratories, identify improvable aspects and, in case of unsatisfactory results, to attend with corrective action.
Il presente rapporto tecnico descrive l’analisi dei risultati ottenuti dai laboratori codificati ACAE, partecipanti al Round Robin Test nel corso del 2016, i quali hanno eseguito una prova di sovratemperatura su un simulacro di interruttore di bassa tensione. Ogni laboratorio partecipante ha effettuato misure di temperatura e di resistenza elettrica sull’oggetto in prova messo a disposizione dalla Bticino S.p.A., circolato per tutti i laboratori partecipanti, ed al cui interno sono state collocate delle barre di rame, in luogo delle normali strutture (contatti mobili e fissi e relativi meccanismi), per renderlo più stabile nel tempo. I laboratori hanno effettuato le prove in accordo alla relativa norma di prodotto (IEC 60947-2), rispettando le prescrizioni del metodo sia per l’allestimento dell’oggetto e sia per l’effettuazione delle misure. Lo scopo del Round Robin test è stato quello di acquisire tutti i dati dei laboratori ed effettuarne una analisi e verificare l’assicurazione di qualità delle misure effettuate, requisito 5.9 della norma ISO/IEC 17025, nonché far emergere criticità dovute alle tecniche di misure, al set-up dell’oggetto in prova e anche le eventuali lacune insite nel metodo di prova. Sulla base dei risultati ottenuti sarà inoltre possibile, a cura dei singoli laboratori, individuare gli aspetti migliorabili ed, in caso di risultati non soddisfacenti, poter intervenire con delle azioni correttive.
Round robin ACAE 2016: valutazione dei risultati delle misure nelle prove di sovratemperatura di interruttori automatici (IEC 60947-2) / Cinnirella, L.; Roccato, P. E.. - (2017).
Round robin ACAE 2016: valutazione dei risultati delle misure nelle prove di sovratemperatura di interruttori automatici (IEC 60947-2)
Cinnirella, L.;Roccato, P. E.
2017
Abstract
This technical report describes the analysis of the results obtained by the ACAE encoded laboratories, participants in the Round Robin Test in the course of 2016, which performed a temperature rise test on a simulacrum of low voltage switch. Each participating laboratory performed measurements of temperature and electrical resistance of the object under test made available by Bticino SpA, circulated to all participating laboratories, and in which were placed the copper bars, instead of the normal structures (contacts mobile and fixed, and related mechanisms), to make it more stable in time. The laboratories have conducted the tests in accordance with the relevant product standard (IEC 60947-2), respecting the requirements of the method for the preparation of the object and both the measuring process. The purpose of the Round Robin test was to capture all the data of the laboratories and to make an analysis and verify the quality assurance of measurements taken, requirement 5.9 of ISO / IEC 17025, as well as bring out critical issues due to technical measures, the object set-up and even the failings inherent in the test method. Based on the results obtained it will also be possible, by the individual laboratories, identify improvable aspects and, in case of unsatisfactory results, to attend with corrective action.File | Dimensione | Formato | |
---|---|---|---|
RT 07.2017.pdf
non disponibili
Tipologia:
accepted manuscript (author’s post-print)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
559.24 kB
Formato
Adobe PDF
|
559.24 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.