The work consists in the comparison of the measurements of the geometrical characteristics of hardness diamond indenters (Vickers and Rockwell) between the INRIM measuring system and the EASYDUR measuring system developed for SIMT, Shanghai, China. The work described in the report was carried out in July 2008, by the Istituto Nazionale di Ricerca Metrologica (INRIM) of Italy (formerly Istituto di Metrologia "G. Colonnetti" (IMGC) of the National Research Council (CNR)) at EASYDUR Laboratory in Induno Olona (VA), Italy. The results have confirmed the capability of the EASYDUR measuring system to calibrate hardness diamond indenters following the ISO standards specifications (ISO 6507-2 and ISO 6508-2).

Comparison of measurements of the geometrical characteristics of hardness diamond indenters between the INRIM measuring system and the Easydur measuring system developed for SIMT (Shanghai-China) / Germak, ALESSANDRO FRANCO LIDIA. - 154:(2008), pp. 1-10. [10.13140/RG.2.1.4514.8005]

Comparison of measurements of the geometrical characteristics of hardness diamond indenters between the INRIM measuring system and the Easydur measuring system developed for SIMT (Shanghai-China)

GERMAK, ALESSANDRO FRANCO LIDIA
2008

Abstract

The work consists in the comparison of the measurements of the geometrical characteristics of hardness diamond indenters (Vickers and Rockwell) between the INRIM measuring system and the EASYDUR measuring system developed for SIMT, Shanghai, China. The work described in the report was carried out in July 2008, by the Istituto Nazionale di Ricerca Metrologica (INRIM) of Italy (formerly Istituto di Metrologia "G. Colonnetti" (IMGC) of the National Research Council (CNR)) at EASYDUR Laboratory in Induno Olona (VA), Italy. The results have confirmed the capability of the EASYDUR measuring system to calibrate hardness diamond indenters following the ISO standards specifications (ISO 6507-2 and ISO 6508-2).
2008
Comparison of measurements of the geometrical characteristics of hardness diamond indenters between the INRIM measuring system and the Easydur measuring system developed for SIMT (Shanghai-China) / Germak, ALESSANDRO FRANCO LIDIA. - 154:(2008), pp. 1-10. [10.13140/RG.2.1.4514.8005]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/34075
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact