Data presented here deal with the measurement of a two-stage Gifford-McMahon cryocooler dynamical thermal response to programmed square wave and sine wave power inputs around 4 K. Square response data report the raw temperature data points measured by the sensor. Properly filtered data are also presented and results of exponential decays fitting analyses are shown as well. Sine response data were acquired with two different experimental setups and at several frequencies; data report the frequencies of the input stimulus, the measured temperature variation and the phase between input and output signals for both setups. More details about the experimental background can be found in the related research article, "Experimental analysis of the thermal behavior of a GM cryocooler based on linear system theory" (Sosso and Durandetto, in press).

Data of cryocooler temperature dynamical response to time-varying power inputs at 4 K / Sosso, Andrea; Durandetto, Paolo. - In: DATA IN BRIEF. - ISSN 2352-3409. - 20:(2018), pp. 1468-1470-1470. [10.1016/j.dib.2018.08.211]

Data of cryocooler temperature dynamical response to time-varying power inputs at 4 K

Sosso, Andrea
;
Durandetto, Paolo
2018

Abstract

Data presented here deal with the measurement of a two-stage Gifford-McMahon cryocooler dynamical thermal response to programmed square wave and sine wave power inputs around 4 K. Square response data report the raw temperature data points measured by the sensor. Properly filtered data are also presented and results of exponential decays fitting analyses are shown as well. Sine response data were acquired with two different experimental setups and at several frequencies; data report the frequencies of the input stimulus, the measured temperature variation and the phase between input and output signals for both setups. More details about the experimental background can be found in the related research article, "Experimental analysis of the thermal behavior of a GM cryocooler based on linear system theory" (Sosso and Durandetto, in press).
File in questo prodotto:
File Dimensione Formato  
Data of cryocooler temperature dynamical response to time-varying power inputs at 4 K - 2018.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione editoriale
Licenza: Creative Commons
Dimensione 119.51 kB
Formato Adobe PDF
119.51 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/65742
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact