To establish a single European railway area, the European Commission requires, by 2019, that energy billings shall be computed on the actual energy consumed. So, in the near future, all the trains shall be equipped with an energy measurement system, whose measurement accuracy should be assessed and periodically reverified, as required by EN 50463-2. As for every energy and power measuring system, the voltage and current transducers play a crucial role as their accuracy could determine the performance level of the entire measurement chain. To answer to this emerging need, this paper presents a calibration system allowing the accurate testing of dc voltage and current transducers, up to 6 kV and 300 A and up to 10 kHz. It is able to reproduce all the tests prescribed by EN 50463-2, but in order to characterize the transducers in actual operating conditions, a series of additional tests can also be performed using synthetic complex waveforms or even signals acquired on-board trains. The expanded uncertainty (level of confidence 95%) of the calibration system is 43 mu ext{V} /V and 24 mu ext{A} /A at dc and 520 mu ext{V} /V and 820 mu ext{A} /A at 10 kHz. Moreover, the calibration of two commercial voltage and current transducers, currently installed in the trains of an Italian operator, is presented. © 1963-2012 IEEE.

Calibration of Voltage and Current Transducers for DC Railway Systems / Crotti, Gabriella; Delle Femine, Antonio; Gallo, Daniele; Giordano, Domenico; Landi, Carmine; Luiso, Mario. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 68:10(2019), pp. 3850-3860. [10.1109/TIM.2019.2912232]

Calibration of Voltage and Current Transducers for DC Railway Systems

Crotti, Gabriella;Giordano, Domenico;
2019

Abstract

To establish a single European railway area, the European Commission requires, by 2019, that energy billings shall be computed on the actual energy consumed. So, in the near future, all the trains shall be equipped with an energy measurement system, whose measurement accuracy should be assessed and periodically reverified, as required by EN 50463-2. As for every energy and power measuring system, the voltage and current transducers play a crucial role as their accuracy could determine the performance level of the entire measurement chain. To answer to this emerging need, this paper presents a calibration system allowing the accurate testing of dc voltage and current transducers, up to 6 kV and 300 A and up to 10 kHz. It is able to reproduce all the tests prescribed by EN 50463-2, but in order to characterize the transducers in actual operating conditions, a series of additional tests can also be performed using synthetic complex waveforms or even signals acquired on-board trains. The expanded uncertainty (level of confidence 95%) of the calibration system is 43 mu ext{V} /V and 24 mu ext{A} /A at dc and 520 mu ext{V} /V and 820 mu ext{A} /A at 10 kHz. Moreover, the calibration of two commercial voltage and current transducers, currently installed in the trains of an Italian operator, is presented. © 1963-2012 IEEE.
File in questo prodotto:
File Dimensione Formato  
Calibration_DC_railway.pdf

non disponibili

Descrizione: Versione Editoriale
Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.08 MB
Formato Adobe PDF
3.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Calibratiom_voltage_current_railway_post_pr.pdf

Open Access dal 01/05/2021

Descrizione: Post Print Version
Tipologia: Documento in Post-print
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 1.93 MB
Formato Adobe PDF
1.93 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/61507
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact