The self-assembly (SA) of diblock copolymers (DBCs) based on phase separation into different morphologies of small and high-density features is widely investigated as a patterning and nanofabrication technique. The integration of conventional top-down approaches with the bottom-up SA of DBCs enables the possibility to address the gap in nanostructured lateral length standards for nanometrology, consequently supporting miniaturization processes in device fabrication. On this topic, we studied the pattern characteristic dimensions (i.e., center-to-center distance L-0 and diameter D) of a cylinder-forming polystyrene-b-poly( methyl methacrylate) PS-b-PMMA (54 kg mol(1), styrene fraction 70%) DBC when confined within periodic SiO2 trenches of different widths (W, ranging between 75 and 600 nm) and fixed length (l, 5.7 mu m). The characteristic dimensions of the PMMA cylinder structure in the confined configurations were compared with those obtained on a flat surface (L-0 = 27.8 +/- 0.5 nm, D = 13.0 +/- 1.0 nm). The analysis of D as a function of W evolution indicates that the eccentricity of the PMMA cylinders decreases as a result of the deformation of the cylinder in the direction perpendicular to the trenches. The center-to-center distance in the direction parallel to the long side of the trenches (L-0l) is equal to L0 measured on the flat surface, whereas the one along the short side (L-0w) is subjected to an appreciable variation (Delta L-0w = 5 nm) depending on W. The possibility of finely tuning L-0w maintaining constant L-0l paves the way to the realization of a DBC-based transfer standard for lateral length calibration with periods in the critical range between 20 and 50 nm wherein no commercial transfer standards are available. A prototype transfer standard with cylindrical holes was used to calibrate the linear correction factor c(Delta x')(xx') of an atomic force microscope for a scan length of Delta x' = 1 m. The relative standard uncertainty of the correction factor was only 1.3%, and the second-order nonlinear correction was found to be significant.

Toward Lateral Length Standards at the Nanoscale Based on Diblock Copolymers / Aprile, Giulia; Ferrarese Lupi, Federico; Fretto, Matteo; Enrico, Emanuele; DE LEO, Maria; Boarino, Luca; Volpe Flavio, Giovanni; Seguini, Gabriele; Sparnacci, Katia; Gianotti, Valentina; Laus, Michele; Garnaes, Jorgen; Perego, Michele. - In: ACS APPLIED MATERIALS & INTERFACES. - ISSN 1944-8244. - 9:18(2017), pp. 15685-15697. [10.1021/acsami.7b00509]

Toward Lateral Length Standards at the Nanoscale Based on Diblock Copolymers

Aprile, Giulia;Ferrarese Lupi, Federico
Writing – Original Draft Preparation
;
Fretto, Matteo
Investigation
;
Enrico, Emanuele
Investigation
;
De Leo Natascia,
Writing – Review & Editing
;
Boarino, Luca
Funding Acquisition
;
2017

Abstract

The self-assembly (SA) of diblock copolymers (DBCs) based on phase separation into different morphologies of small and high-density features is widely investigated as a patterning and nanofabrication technique. The integration of conventional top-down approaches with the bottom-up SA of DBCs enables the possibility to address the gap in nanostructured lateral length standards for nanometrology, consequently supporting miniaturization processes in device fabrication. On this topic, we studied the pattern characteristic dimensions (i.e., center-to-center distance L-0 and diameter D) of a cylinder-forming polystyrene-b-poly( methyl methacrylate) PS-b-PMMA (54 kg mol(1), styrene fraction 70%) DBC when confined within periodic SiO2 trenches of different widths (W, ranging between 75 and 600 nm) and fixed length (l, 5.7 mu m). The characteristic dimensions of the PMMA cylinder structure in the confined configurations were compared with those obtained on a flat surface (L-0 = 27.8 +/- 0.5 nm, D = 13.0 +/- 1.0 nm). The analysis of D as a function of W evolution indicates that the eccentricity of the PMMA cylinders decreases as a result of the deformation of the cylinder in the direction perpendicular to the trenches. The center-to-center distance in the direction parallel to the long side of the trenches (L-0l) is equal to L0 measured on the flat surface, whereas the one along the short side (L-0w) is subjected to an appreciable variation (Delta L-0w = 5 nm) depending on W. The possibility of finely tuning L-0w maintaining constant L-0l paves the way to the realization of a DBC-based transfer standard for lateral length calibration with periods in the critical range between 20 and 50 nm wherein no commercial transfer standards are available. A prototype transfer standard with cylindrical holes was used to calibrate the linear correction factor c(Delta x')(xx') of an atomic force microscope for a scan length of Delta x' = 1 m. The relative standard uncertainty of the correction factor was only 1.3%, and the second-order nonlinear correction was found to be significant.
File in questo prodotto:
File Dimensione Formato  
2017_ACS_AMI_Standard_EditorialVersion.pdf

non disponibili

Tipologia: Versione editoriale
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.42 MB
Formato Adobe PDF
2.42 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2017_ACS_AMI_Standard_SubmittedVersion.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 2.03 MB
Formato Adobe PDF
2.03 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/56911
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 14
social impact