A proficiency test through interlaboratory comparison of radiated emission measurements was carried out in the period of time comprised between May 2012 and May 2013. Nineteen test houses took part in the exercise providing 91 measurement results in total. Measurements were performed in anechoic chambers and in the frequency range comprised between 200 and 3000 MHz. A traveling sample circulated among the laboratories, generating a reference electromagnetic field whose amplitude was a priori known (with uncertainty) but not revealed to the participants until the end of the comparison. Measurement results were provided by the participants in terms of best estimate and uncertainty. The aggregate measurement result is here compared with the a priori known value and its uncertainty. The performance of the laboratories, quantified in terms of two performance statistics selected from ISO 13528, is analyzed and discussed. The measurement uncertainty declared by the laboratories is compared with the dispersion of the measurement results. Aspects concerning the design and conduct of the comparison are also presented and discussed.

Design, Preparation, Conduct, and Result of a Proficiency Test of Radiated Emission Measurements / Carobbi, Carlo F. M.; Bonci, Alessio; Cati, Marco; Panconi, Carlo; Borsero, Michele; Vizio, Giuseppe. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - 56:6(2014), pp. 1251-1261. [10.1109/TEMC.2014.2326732]

Design, Preparation, Conduct, and Result of a Proficiency Test of Radiated Emission Measurements

BORSERO, MICHELE;
2014

Abstract

A proficiency test through interlaboratory comparison of radiated emission measurements was carried out in the period of time comprised between May 2012 and May 2013. Nineteen test houses took part in the exercise providing 91 measurement results in total. Measurements were performed in anechoic chambers and in the frequency range comprised between 200 and 3000 MHz. A traveling sample circulated among the laboratories, generating a reference electromagnetic field whose amplitude was a priori known (with uncertainty) but not revealed to the participants until the end of the comparison. Measurement results were provided by the participants in terms of best estimate and uncertainty. The aggregate measurement result is here compared with the a priori known value and its uncertainty. The performance of the laboratories, quantified in terms of two performance statistics selected from ISO 13528, is analyzed and discussed. The measurement uncertainty declared by the laboratories is compared with the dispersion of the measurement results. Aspects concerning the design and conduct of the comparison are also presented and discussed.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/50934
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 30
social impact