In the framework of the longitudinal spin Seebeck effect (LSSE), we developed an experimental setup for the characterization of LSSE devices. This class of device consists in a layered structure formed by a substrate, a ferrimagnetic insulator (YIG) where the spin current is thermally generated, and a paramagnetic metal (Pt) for the detection of the spin current via the inverse spinHall effect. In this kind of experiments, the evaluation of a thermal gradient through the thin YIG layer is a crucial point. In this work, we perform an indirect determination of the thermal gradient through the measurement of the heat flux. We developed an experimental setup using Peltier cells that allow us to measure the heat flux through a given sample. In order to test the technique, a standard LSSE device produced at Tohoku University was measured. We find a spin Seebeck SSSE coefficient of 2.8 10^-7 V K^-1 .

Evaluation of thermal gradients in longitudinal spin Seebeck effect measurements / Sola, Alessandro; Kuepferling, Michaela; Basso, Vittorio; Pasquale, Massimo; Kikkawa, T.; Uchida, K.; Saitoh, E.. - In: JOURNAL OF APPLIED PHYSICS. - ISSN 1089-7550. - 117:(2015). [http://scitation.aip.org/content/aip/journal/jap/117/17/10.1063/1.4916762]

Evaluation of thermal gradients in longitudinal spin Seebeck effect measurements

Sola Alessandro;Kuepferling Michaela;Basso Vittorio;Pasquale Massimo;
2015

Abstract

In the framework of the longitudinal spin Seebeck effect (LSSE), we developed an experimental setup for the characterization of LSSE devices. This class of device consists in a layered structure formed by a substrate, a ferrimagnetic insulator (YIG) where the spin current is thermally generated, and a paramagnetic metal (Pt) for the detection of the spin current via the inverse spinHall effect. In this kind of experiments, the evaluation of a thermal gradient through the thin YIG layer is a crucial point. In this work, we perform an indirect determination of the thermal gradient through the measurement of the heat flux. We developed an experimental setup using Peltier cells that allow us to measure the heat flux through a given sample. In order to test the technique, a standard LSSE device produced at Tohoku University was measured. We find a spin Seebeck SSSE coefficient of 2.8 10^-7 V K^-1 .
File in questo prodotto:
File Dimensione Formato  
Sola_JAP_2015.pdf

accesso aperto

Descrizione: This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article may be found at DOI indicated above.
Tipologia: Versione editoriale
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 1.77 MB
Formato Adobe PDF
1.77 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/29666
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 37
social impact